Section 3: Installation & Setup
CP2000-M/MR Setup Guide 3-11
020-100205-03 Rev. 1 (05/09)
3.10 ADJUSTING TILT AND LEVELING
For an ideal installation, the lens surface should be centered and parallel to the screen - this orientation
helps to ensure optimized lens performance with minimal offset. Choose a sturdy mounting surface. If
this position is not possible (such as when the projector is significantly higher than the center of the
screen), it is better to rely on offset rather than extra tilt.
3.10.1Adjusting Tilt
IMPORTANT! The front-to-back tilt of the projector must not exceed 15°. This limit ensures safe lamp
operation and proper position of the liquid cooling reservoir. For best optical performance, avoid
tilting the projector excessively. Use vertical offset of the lens instead.
Before adjusting tilt, ensure the projector is centered as much as possible to the theatre screen. Check
with theatre personnel for the degree of screen tilt, or measure this incline with a protractor at the
screen. Then tilt the projector to closely match the screen tilt angle by extending or retracting the
projectors 4 adjustable feet.
3.10.2Adjusting Feet/Leveling
To adjust the height and level of the projector, extend or
retract the feet by rotating them (Figure 3-10). Once
the required adjustment is made tighten the lock nut.
The 2 back feet measure 203mm (8”) in order to
achieve a 15° tilt when necessary. NOTE: When
installing the CP2000-M/MR on the rack stand (108-
282101-xx or 108-272101-xx) the foot lock brackets
(119-100101-xx) must be installed for safety purposes.
3.10.3Carrying/Moving the Projector
2 people are required to safely lift and carry 1
projector a short distance. Titling the projector
excessively should be avoided as it can introduce air
bubbles within the coolant hoses, which can lead to an
air lock.
CAUTION
Disconnect from AC for these initial alignments. Images are not yet needed.
FIGURE 3-10 LEVELING