Section 2: Installation and Setup
CP2000 Setup Guide 2-5
020-100070-01 Rev. 1 (10/08)
1. Open both pedestal doors (Figure 2-5).
2. From the projection head, open the rear side door on the operator's side and open the lamp door
(Figure 2-5).
FIGURE 2-5 OPEN PROJECTOR FOR ACCESS
3. SET BALLAST AC INPUT SWITCH: Before connecting the ballast to AC, set the ballast’s AC input
switch to match the AC available at the site—toggle left for nominal 200 VAC supplies, and toggle
right for 400 VAC supplies. The factory default is 200 VAC.
4. Ballast ‘RS-232’ Cable: Connect the ballast's ‘RS-232’ cable 34-002075 to Panel B (9-pin),
routing through the small rectangular access hole in the front underside of the projection head
(Figure 2-6 Connect Ballast RS-232 and Interlocks to Projection Head). A second connector on
Panel B is pre-connected to Panel C. Any third connector is a non-functional spare.
5. Ballast Interlock Cable: Connect the ballast's interlock cable 34-002007 to Panel C (9-pin),
routing through the small rectangular access hole in the rear underside of the projection head
(Figure 2-6 Connect Ballast RS-232 and Interlocks to Projection Head). A second connector on
Panel C is pre-connected to Panel B and the remaining third connector is a non-functional spare.
FIGURE 2-6 CONNECT BALLAST RS-232 AND INTERLOCKS TO PROJECTION HEAD
NOTE: These cables also connect to the fire alarm interlock and dedicated outlet (both pre-connected
at manufacture).