4-4 CP2000-M/MR Setup Guide
020-100205-03 Rev. 1 (05/09)
Section 4: Maintenance
4.3 LENS REPLACEMENT
4.3.1 REMOVE LENS
1. Power down the projector. Allow the fans to cool the lamp before unplugging the projector. If
necessary, a lens can be swapped out while the projector is running, but this can result in dust
being drawn into the projector. Avoid if possible.
FIGURE 4-3 LENS ASSEMBLY
2. Install the lens cap (Figure 4-4, 1) and release the lens clamp by pushing it up (Figure 4-4, 2).
FIGURE 4-4 RELEASE LENS CLAMP
3. If necessary, remove the 2 capscrews securing the lens to the lens mount (Figure 4-4, 3).
4. Pull the lens out of the lens mount. The lens, motorized zoom and focus connectors disconnect
when the lens is pulled straight from the mount.