2-6 CP2000-ZX Setup Guide
020-100098-04 Rev. 1 (06-2009)
Section 2: Installation & Setup
For CDXL-20 lamps: Move the lamp cradle as far for-
ward as possible (position closest to igniter).
For CDXL-30 and CDXL-30SD lamps: Move the
lamp cradle to the rear position, which is approxi-
mately 1” closer to the reflector.
For CDXL-30SD lamps only, you must use the
extension nut provided (at the cathode end) to ensure
correct placement. NOTE: Retain the extension nut for
future lamp replacements since this part is not part of a
new lamp assembly.
3. Install the lamp.
Refer to Section 4
Maintenance for lamp replacement
instructions. Observe all warnings, and wear protective
clothing and shielding.
Important! Before striking the lamp for the first time, you
must use the CDP Lamp menu to enter important lamp
information, such as lamp type, serial number and number
of hours the lamp is used (if any). If this is not done, the
lamp will not be recorded in the system and the lamp power
of the bulb will not be set properly.
STEP 8 - Connect to Power
CP2000-ZX is designed as a permanently wired connection or pluggable type B connection (P/N 116-102104-
01). Connecting the projector to your AC supply can vary according to the country or state in which the
projector is installed. For any installation, always follow the electrical code for your location.
1) Certified electrician required. 2) Ground (earth) connection is necessary for
safety. Never compromise safety by returning current through the ground. 3) Connect ground
FIRST
to reduce shock hazard from high leakage. 4) Protection from overcurrents, short
circuits and earth faults must be part of the building installation. Disconnect device (double
pole switch or circuit breaker with minimum 3mm contact gap) must be readily accessible
within the projection room. 5) Do not use a wall breaker greater than 32A.
Use an appropriate strain relief connector on the AC supply cable to prevent
the cable from rubbing against the projector knockout plate and becoming damaged.
To install a permanent connection, refer to
Installing a Permanent Connection below.
To install a Pluggable type B connection using a Nema-L630A 250V Power Plug, refer to
Installing a
Pluggable Type B Connection below.
Figure 2-9 Anode Yoke Location