4-6 CP2000-ZX Setup Guide
020-100098-04 Rev. 1 (06-2009)
Section 4: Maintenance
STEP 10: Web UI Adjustments
In the Advanced: Lamp History menu, select New Lamp and record lamp type, serial and number of the
hours logged on to the lamp (“0” if it hasn’t previously been used).
STEP 11: Turn Lamp ON
Press LAMP ON on the CDP.
STEP 12: Adjust LampLOC™
Immediately adjust lamp position (LampLOC™). This can be done via the CDP Lamp menu or via the
Advanced: Lamp menu. By adjusting lamp position, you can achieve optimized light output - the lamp
(bulb) is well-centered with the reflector and distanced correctly from the center of the illumination sys-
tem.
4.4 Replacing the Filter
Use only special, high efficiency Christie approved filters. Never operate the
projector without the filter installed.
Always discard used air filters.
Replace the air filter whenever the lamp module is replaced or sooner if operating the projector in a dusty or
dirty environment. Check monthly in all cases. The filter is located on the inputs side of the projector, behind
the air filter cover. To replace:
1. Release two tabs on the air filter cover and remove.
2. Slide the air filter out and discard. Insert the new air filter with the airflow indicator facing toward the
projector. Never reuse an old air filter. The air filters in this product cannot be cleaned thoroughly enough
for reuse and can lead to the contamination of optical components.
3. Replace the air filter cover by inserting the two bottom tabs into place first and snapping the door closed.
4.5 Replacing a Lens
A variety of primary lenses can accommodate different throw distances and specific types of installations –
refer to Section 6: Specifications in the CP2000-ZX User Manual (020-100006-xx). When replacing or
switching out a lens, do the following:
1. Release the lens locking lever (UP position)
2. Pull out lens and replace with a different high-brightness or high-contrast lens. NOTE: Always install the
lens with “UP” label in the top position. This will assist in achieving consistent boresight alignment each
time the lens is replaced. See Section
STEP 6 - Install Lens(es), on page 2-5.
3. Secure with lens locking lever (DOWN position).
4. Secure with lens locking lever (DOWN position).
5. Calibrate the lens. Refer to Section 2.7 Basic Image Alignment in the CP2000-ZX User Manual (020-
100006-xx) for details.