Section 2: Installation and Setup
CP2000 Setup Guide 2-15
020-100070-01 Rev. 1 (10/08)
342-456 VAC (Europe, etc.):
If 3-phase and single-phase feeds (6-wire):
Ensure ground wire is connected directly to the frame ground lug on the pedestal floor.
Attach no other wires here.
Connect L and N @ 200-230 VAC (single-phase)
Connect 1, 2, and 3 @ 342-456 VAC (3-phase)
If 3-phase with neutral fed from 3-phase (5-wire):
Ensure ground wire is connected directly to the frame ground lug on the pedestal floor.
Attach no other wires here.
Connect 1, 2, 3, and N @ 342-456 VAC (3-phase)
No L available. Connect jumper from 1 to L.
If 3-phase only (4-wire):
This configuration is not possible. Use 5-wire or 6-wire only. Neutral is required.
SPECIAL ADJUSTMENTS FOR SOME AC SUPPLIES
AC levels can vary depending on region. Check the following when installing.
NOTES: 1) Requires voltmeter for up to 400 VAC. 2) Consult the Interconnect Drawing in pedestal.
Jumper from Igniter Terminal 2: As set from the factory, the igniter jumper located on terminal 2
connects to T2. This configuration is used when 207-265 VAC are present (as it is for most countries).
If you find your incoming AC is below 207 VAC, connect terminal 2 jumper to T1 instead.
FIGURE 2-21 CHECK VOLTAGE AND POSITION JUMPERS
WARNING
Ground (earth) connection is necessary for safety. Never compromise safety by
returning current through the ground.