Section 4: Maintenance
CP2000 Setup Guide 4-9
020-100070-01 Rev. 1 (10/08)
3. Tighten set screws in both negative and positive lamp connectors (Figure 4-2 Secure bulb at
cathode (-) and anode (+) connectors).
IMPORTANT! Proper electrical contact prevents resistance in the lamp connectors.
If you accidentally touch the quartz body of the lamp with your bare hands, clean it as described in 4.3
Maintenance and Cleaning.
FIGURE 4-2 SECURE BULB AT CATHODE (-) AND ANODE (+) CONNECTORS
CHECK LEADS
Ensure the anode (+) lead between the lamp and igniter is well away from any projector metal, such as
the reflector or firewall.
CLOSE COOLING COMPARTMENT AND LAMP DOOR
The projector will not operate unless the louvered door is locked shut.
TURN BREAKERS ON
At the projector's breaker panel, turn all breakers ON.
WARNING
Leads too close to metal parts will cause arcing during starting pulse. This is a SAFETY
HAZARD and the lamp may not ignite.