Christie CP2000-X Guide d'installation Page 57

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 64
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 56
Section 4: Maintenance
CP2000 Setup Guide 4-11
020-100070-01 Rev. 1 (10/08)
4. With the filter in place, insert the bottom tabs of the filter door into the corresponding slots. Close
the filter door and secure with the two screws removed in Step 2.
FIGURE 4-3 AIR FILTER REPLACEMENT
4.5 LENS REPLACEMENT PROCEDURE
A variety of primary lenses can accommodate different throw distances and specific types of
installations.
1. Release the lens locking lever (UP position).
2. Pull out lens and replace with a different high-contrast primary lens, as described in 2.1
Assembly and Connection of Components.
3. Secure with lens locking lever (down position).